Performance Characteristics
Mechanical properties
Serial Number
| Item
| Index
|
1
| Short-term hydrostatic test
| Testing conduct under C/T189-2007
requirement, temperature 20 ℃, liquid pipe 2.0 Mpa nominal pressure, gas
pipe 3.2 Mpa nominal pressure, testing time 1 hour. All pipes no
fracture & no leakage. |
Testing conduct under C/T189-2007
requirement, temperature 80 ℃, liquid pipe 1.2 Mpa nominal pressure, gas
pipe 1.92 Mpa nominal pressure, testing time 165 hours. All pipes no
fracture & no leakage.
|
Testing conduct under C/T537-2019
requirement, temperature 60 ℃, 1.05 Mpa nominal pressure, testing time
165 hours. The pipe no fracture & no leakage. |
2
| Burst Pressure
| Testing temperature 20 ℃, rise the
pressure to burst in 60-70 seconds, the bursting pressure is ≥3 times of
the nominal pressure. |
3
| Negative pressure resistance test | Testing negative pressure 0.097 Mpa, keeping 100 hours. Pipe performs no damage or transformation. |
4
| Pressure cracking stability | When press to 50% of nominal diameter in 10-15 seconds, the pipe doesn't crack or damage.
|
5
| Peel strength
| ≥100N/cm |
Note: Above
performance is normalization requirements, in order to explain the
standard of features. And the negative pressure resistance test only
applicable to gas extraction pipe.
|
Flame retardant and antistatic properties
Serial number | Item | Index
|
1
| Surface resistance
| Water supply & drainage pipe: the arithmetic mean value of outer surface should ≤10x109Ω.
|
Positive pressure air pipe: the arithmetic mean value of outer surface should ≤10x108Ω. |
Pipe for shotcrete: the arithmetic mean value of outer surface should ≤10x108Ω. |
Negative pressure air pipe: the arithmetic mean value of outer surface should ≤10x106Ω.
|
Gas extraction pipe: the arithmetic mean value of outer surface should ≤10x106Ω. |
2
| Alcohol burner burning | The arithmetic mean value of flame burning time for 6 tested pipes should ≤3 seconds. Single pipe should ≤ 10 seconds. |
The arithmetic mean value of flameless burning time for 6 tested pipes should ≤20 seconds. Single pipe should ≤ 60 seconds. |